Condition Monitoring Unit CMU 1000

Page 48

Revised 17.12.2009

HYDAC ELECTRONIC GMBH Mat.-No.:

669749

5.2.5 Actions

5.2.5.1 Display Device Status

Status

The "Status" indicates the current condition of the device. The individual
conditions can be be specified in greater detail via the following table.

Ready

No active error present, device is ready for operation

Stand-By

No active error present, but device is currently not ready for
operation; it may be that individual device functions are switched
off or the device is in a startup phase, etc.

Minor error

A minor error is present which can be acknowledged.

Moderate error

A medium-serious error is present, which may possibly be
eliminated by switching On/Off.

Serious error

A serious error is present; the unit must be sent in to the
manufacturer.

Status code

The "Status code" is dependent on the CM Program present in the device and
reflects the conditions of the Boolean output values used in the program.
For this, the Boolean output values are displayed from right to left in ascending
binary sequence, i.e. the lowest-value bit corresponds to the Boolean output
value 0.

Example:
0 = No Boolean output values used in the program
1 0 1 0 = Boolean output value 0 = 0 (LSB)
Boolean output value 1 = 1
Boolean output value 2 = 0
Boolean output value 3 = 1

Status text

The "Status text" indicates whether or not a CM Program is available in the
device.

No script loaded

No CM Program is available in the device.

Script in execution

A CM Program is available in the device.