Condition Monitoring Unit CMU 1000

Page 42

Revised 17.12.2009

HYDAC ELECTRONIC GMBH Mat.-No.:

669749

5.2.3.3 Connection Setup with CMU 1000 using GSM Mobile Network

• Start the HYDAC PC software CMWIN
• In the Units Menu, select the "CM Manager" option.


• If the Connection window does not open automatically, select

"Connection" in the menu bar of the CM Manager.

• Mark the "Modem Connection" option in the window that opens.
• Click on "Change" to open the window for the interface settings.


• Make the corresponding preselection for the port settings in the window that

opens under Interface selection.

• Select the respective port address and Baud rate under Interface settings.
• Pressing "Refresh" causes the interfaces marked under Interface selection to

be refreshed in terms of availability.

• Click on “OK“ to apply the modified settings or “Cancel“ to discard these

changes. In either case you will then return to the Connection window.


• Click on "Change" to open the window for entering the telephone numbers.


• Enter the telephone number of the SIM card mounted in the GSM module

CSI-F-10.

• In the Pin box, input the pin code given for the SIM card which is operated in

the GSM modem in the PC (not for the SIM card in the CSI-F-10!). If no PIN
code has been assigned, then leave this box empty.