8.1 Overriding Error Messages
8.1.1 Function not Available in this Mode
The CM program was compiled for a platform in which the marked function does not
exist.
► Check the platform setting and correct it or modify the CD program accordingly.
8.2 Error Messages with Data Sources
8.2.1 Invalid Channel Setting
A channel/subchannel was selected that is not valid.
► Check the channel setting and correct it.
8.2.2 Duplicate Channel Name
The name of a channel may only be used once in a CM program.
► Check the channel name and correct it.
8.2.3 Invalid Digital Input
A port must be set with the Digital input function.
► Check the port setting and correct it.
8.2.4 Duplicate Digital Input
A port must be set with the Digital input function. This port that is set may only be
used once in a CM program.
► Check the port setting and correct it.
8.2.5 Too many Boolean Input Fields
No more than a maximum of 50 Boolean input values are permitted to be present in a
single CM program.
► Reduce the Boolean input values to a maximum of 50.
8.2.6 No Inscription with Boolean Input
The Boolean input value must have an inscription.
► Enter an inscription in the function properties.
8.2.7 Duplicate Inscription with Boolean Inputs
The inscription of a Boolean input value must be unambiguous within a CM program
and is only permitted to occur once for that reason.
► Check the inscription and correct it.
8.2.8 Too Many Numerical Input Values
No more than a maximum of 50 numerical input values are permitted to be present in
a single CM program.
► Reduce the numerical input values to a maximum of 50.