HYDAC CMU 1000 User Manual
Page 119

Condition Monitoring Unit CMU 1000
Page 119
Revised 17.12.2009
HYDAC ELECTRONIC GMBH Mat.-No.:
669749
9.9.5 Serial Interface 0 (UART 0)
The serial interface 0 of the calculation unit is used either for implementation of an
RS 232 or of an HSI Master interface (see below). The switchover can be programmed
freely (optional IO link also possible). The connection is accomplished using plug-in
terminals. No handshake lines.
9.9.6 HSI Master
HSI interface for cascading the CMU. The HSI Master interface is linked with an HSI
sensor interface of the superordinate SMU for this purpose.
9.9.7 USB Device
USB 1.1 / USB 2.0 full speed interface for connecting a PC/laptop for configuration of
the CMU; connection socket Type "B".
9.9.8 CAN Bus Interface
A CAN Bus interface can be integrated as an option.
9.9.9 IO Link Interface
A IO link interface can be integrated as an option.
9.10 Cycle Time
The CMU determines automatically the required cycle time when the program starts.
The user has the option of having the current cycle time displayed on the CM Editor.
The display shows rounded values (e.g. 10 ms instead of the 8.7 ms detected).
9.11 Operating and Ambient Conditions
Operating temperature: -20.. +70°C
Storage temperature:
-30.. +80°C
Relative moisture:
0 .. 70%, non-condensing
9.12 Dimensions and Weight:
Dimensions: approx. 212 x 105 x 32 mm (W x H x D)
Weight:
approx. 600 g
9.13 Technical Standards
EMV: EN
61000-6-1/2/3/4
Safety:
EN
61010
Protection type:
IP 40