Diagnostics using Profile S-7.5.5
11.4.1
Binary data
11.4.2
Transparent input data
Channel 0 of the transparent input data describes the status of both AS-i circuits.
The upper 8 bits describe the status of the AS-i 2 circuit and the lower 8 bits that
of the AS-i 1 circuit.
In channel 1 and 2 the colors of the release circuits follow (at present only 2 are
used).
Information!
The old diagnostics for the Safety Monitor is no longer supported.
D3
D2
D1
D0
Monitor->
Master (input)
Serial
communication
Serial
communication
1: Output 2 either
turned off or
flashing green
1: Output 1 either
turned off or
flashing green
Master->
Monitor (output)
Change from 0 to
1 resets the fault
lamp AS-i 2
Change from 0 to
1 resets Circuit 1
fault lamp
Serial
communication
Serial
communication
Tab. 11-4.
Channel
2
15
2
14
2
13
2
12
2
11
2
10
2
9
2
8
0
AS-i circuit 2
AU
RD
YE
GN
UA
DA
EF
1
Status OSSD 4
Status OSSD 3
2
Status OSSD 8
Status OSSD 7
3
OSSD 8
OSSD 7
OSSD 6
OSSD 5
RF
YF
RF
YF
RF
YF
RF
YF
Tab. 11-5.
Channel
2
15
2
14
2
13
2
12
2
11
2
10
2
9
2
8
0
AS-i circuit 1
RD
YE
GN
UA
DA
EF
1
Status OSSD 2
Status OSSD 1
2
Status OSSD 6
Status OSSD 5
3
OSSD 4
OSSD 3
OSSD 2
OSSD 1
RF
YF
RF
YF
RF
YF
RF
YF
Tab. 11-6.