Installation, 1 dimensions, 2 connections – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual
Page 27: Dimensions, Connections
AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
Installation
Subject to reasonable modifications due to technical advances
Id.-No.: 103329
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
27
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
5.
Installation
5.1
Dimensions
5.2
Connections
96
Warning!
Cover the top of the gateway when doing any drilling work above the unit. No particles,
especially metal chips, should be allowed to enter the housing, since this could cause a
short circuit.
Information!
Please refer to installation instruction for this device for detailed mounting information.
5 ... 6 mm / PZ2
0,8 Nm
7
LB.IN
2 x (0,5 .... 1,5) mm
2
2 x (0,5 .... 1,5) mm
2
AWG
2 x 24 ...12
10
10
Attention!
The AS-I power supply for the AS-I components must have isolation per IEC 60
742 and be able to handle momentary power interruptions of up to 20 ms. The
power supply for the 24 V supply must also have isolation per IEC 60 742 and be
able to handle momentary power interruptions of up to 20 ms. The maximum out-
put voltage of the power supply must also be less than 42 V in case of a fault.