In-/output – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual
Page 153
AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
Appendix: Example for startup on a Siemens S7
Subject to reasonable modifications due to technical advances
Id.-No.: 103329
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
153
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
17.2.3
Configuring AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
in-/output
If the AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor is added to the
PROFIBUS using drag and drop, the Step7 hardware configuration shows the fol-
lowing graphic.
At this point the desired PROFIBUS communication module should be parame-
terrised. This is done in the following steps:
1.
Select the AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor by
clicking on the Slave icon. In the lower edge of the screen a table is shown
which contains lines beginning with Slot 0.
2.
Select the desired communication module "Flags + Fault Detector" from the
hardware catalog. These flags use the individual bits to signal the operating
status of the AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
and should be processed in the application program.