Status indication, faults and fault elimination, Spontaneous display of faults from the safety unit – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual
Page 136
136
Subject to reasonable modifications due to technical advances
Id.-No.: 103329
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
Status indication, faults and fault elimination
14.
Status indication, faults and fault elimination
14.1
Spontaneous display of faults from the safety unit
Spontaneous messages are displayed on Euchner GmbH + Co. KG AS-i moni-
tors as follows:
•
When both networks are operating without error, a smiley is displayed.
•
When field bus communication fails, this is indicated by a text message.
•
When there is a fault on an AS-i slave, this is displayed until the fault is no
longer present.
•
When there are no faults present, the states of the safety unit are displayed in
text beneath the smiley.
•
When four local release circuits are present, a line is displayed with their sta-
tus.
Coding:
Display in protecting mode:
1, 2, 3 and 4 for the release circuits
Red and flashing yellow are fault messages and are treated separately.
If the safety unit is in configuration mode, this is indicated by the CONFIG-OPER-
ATION display.
Yellow flashing and red flashing means the AS-i slave address of the faulted de-
vice is displayed. If there are other faults present at the same time, all faults are
displayed alternatingly.
Naming:
If the safety unit is in the red flashing state and no menu is open, the safety unit
can be unlocked by pressing the ESC/Service key (Section
☺Press OK for Menu
Output Circuit
1:ON 2:ON
3:ON 4:ON
ON:
green
–
turned on
OFF:
red
–
turned off
WAIT: flashing green
–
Wait time Stop 1 running
START: yellow
–
waiting for Start signal
flashing red: SAFETY FAULT!
flashing yellow: TEST!