8 los (list of offline slaves), 9 chipcard, Los (list of offline slaves) – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual
Page 113: Chipcard
AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
Operation in advanced display mod
Subject to reasonable modifications due to technical advances
Id.-No.: 103329
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
113
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
9.9.8
LOS (list of offline slaves)
Main menu || SETUP || LOS LIST OF OFFLINE SLAVES ||
See also
By using "Clear all" and "Set all" all bits in this list can be delete or set, respective-
ly, at the same time. Below this is a list of all slaves that can be selected individu-
ally in order to set or delete the LOS bit.
9.9.9
CHIPCARD
Main menu || SETUP || CHIPCARD ||
This function is used to send unsafe AS-i data between the master and chip card.
In addition, the unsafe section of the chip card can be deleted.
For additional information refer to chap.
LOS LIST OF
OFFLINE SLAVES
CLEAR ALL
SET ALL
| 1A- X
2A- | 3A-
4A-X | 5A- X
....
30A-X | 31A-
| 1B- X
2B- X | 3B- X
4B- X | 5B- X
....
30B- X | 31B- X
Empty field: LOS bit deleted
X: LOS bit set
CHIPCARD
CARD -> MASTER
MASTER -> CARD
CLEAR CHIPCARD
CHIPCARD->MASTER: Chip card data are copied to the Monitor
MASTER->CHIPCARD: Monitor data are copied to the chip card
CLEAR CHIPCARD: Chip card data are cleared