EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual
Page 123
AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor
PROFIBUS DP
Subject to reasonable modifications due to technical advances
Id.-No.: 103329
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
123
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
Possible options:
Length
1
1.Possible for 2 circuits
description
4 byte I
digital input (slave 0 - 7)
8 byte I
digital input (slave 0 - 15)
12 byte I
digital input (slave 0 - 23)
16 byte I
digital input (slave 0 - 31)
20 byte I
digital input (slave 0 - 7b)
24 byte I
digital input (slave 0 - 15B)
28 byte I
digital input (slave 0 - 23B)
32 byte I
digital input (slave 0 - 31B)
Tab. 11-10.
Length
1
1.Possible for 2 circuits
description
4 byte O
digital output (slave 0 - 7)
8 byte O
digital output (slave 0 - 15)
12 byte O
digital output (slave 0 - 23)
16 byte O
digital output (slave 0 - 31)
20 byte O
digital output (slave 0 - 7B)
24 byte O
digital output (slave 0 - 15B)
28 byte O
digital output (slave 0 - 23B)
32 byte O
digital output (slave 0 - 31B)
Tab. 11-11.
Length
1
1.Possible for 2 circuits
description
16 byte I/O
digital in/out (slave 0 - 31)
16 byte I/O
digital in/out (slave 0b - 31b)
32 byte I/O
digital in/out (slave 0 - 31b)
Tab. 11-12.
Information!
Up to eight command interfaces can be integrated.