Link time, Finishing the sequence – ETC Desire Series v1.6.0 User Manual User Manual
Page 72

66
Desire Series v1.6.0 User Manual
Figure-4.26 Selecting Preset on the Sequences Menu.
Step 2:
Press [
] or [
] to set the desired Preset number.
Step 3:
Press [
].
Step 4:
Press [
] to scroll to Link Time.
Link Time
Link Time is the length of time the fixture waits before moving from one Preset to the next.
The format is MM:SS. The default is 2 seconds.
Step 1:
On the Sequences menu, scroll to Link Time and press [
].
Figure-4.27 Selecting Link Time on the Sequences Menu.
Step 2:
Press [
] or [
] to set the desired time in minutes.
Step 3:
Press [
].
Step 4:
Press [
] or [
] to set the desired time in seconds.
Step 5:
Press [
] to commit the values.
Finishing the Sequence
After each of the steps have been configured, set the End State. End state is what the
fixture does once it completes the Sequence. Two end state options are available and both
options repeat indefinitely until the Sequence is deactivated. To access the end state
options, you must first program an additional and final step within the sequence using
Preset 0. Preset 0 marks the end of the Sequence and opens the End State menu line.
Preset 0 may only be used once within a Sequence. If you want the Sequence to repeat
automatically, you may only define up to 23 steps with Presets 1 through 24, since the final
step must be reserved for Preset 0.
Loop
Once the fixture completes the entire sequence, it immediately returns to the beginning and
starts the sequence over again, in order.
Bounce
Once the fixture completes the entire sequence, it reverses the order of the presets and
steps backward through them until reaching the starting step, at which point it starts the
Sequence over again, in the original order.
Sequences
Sequence:
*3
Action: Not
Active
Rate: 100%
Step: 01
Preset
: 1
Link Time: 00:02
Copy to Other Fixture
Sequences
Sequence:
*3
Action: Not
Active
Rate: 100%
Step: 01
Preset: 1
Link Time
: 00:02
Copy to Other Fixture