Power and data cabling requirements, Power, Data (d40, d40xt, d60) – ETC Desire Series v1.6.0 User Manual User Manual
Page 32: Power data (d40, d40xt, d60)
![background image](/manuals/559127/32/background.png)
26
Desire Series v1.6.0 User Manual
Power and Data Cabling Requirements
Power
The Desire series fixture operates on AC power, 100 to 240VAC/50-60Hz. The fixture must
be connected to a non-dimmable power source in order to avoid damage to its internal
power supply and other electrical components.
Data (D40, D40XT, D60)
The Desire series fixtures operate on a DMX control signal or as standalone fixtures. The
fixture is supplied with a 5-pin XLR DMX input connector and a 5-pin DMX Thru connector.
DMX cables should be acceptable for DMX data transmission (not microphone cable) and
should follow the standard pinout. The optional secondary data pair is not used by the
Desire series fixtures. The maximum DMX data run from any DMX source to the last fixture
in a chain is 1000 feet (300m). Termination is required for the D40XT in the data thru port
of the last fixture in each data chain. The D40 and D60 are self-terminated.
See
for additional information on DMX addressing of Desire Series
fixtures.
Mains
Europe
North America
Line
Brown
Black
Neutral
Blue
White
Ground (Earth)
Green/Yellow
Green
DMX512 pinout for five-pin XLR female
1
Common (Shield)
2
Data –
3
Data +
4
not connected
5
not connected
Push
1
2
3
4
5