beautypg.com

Enerpac ATP-Series User Manual

Page 3

background image

3

3.0 SPECIFICATIONS

3.1

Performance Data

3.2 Technical Data

Temperature

Range

Oil Viscosity

Range

Hydraulic

Oil Type

(recommended)

Seal

Materials

Max Hyd.

Pressure

(operating)

Sound Level

Air

Consumption*

(typical)

Weight

(including

oil)

-20 to +140ºF

[-29 to +50ºC]

150 -165 S.U.S.

[15 - 25 C.S.T.]

Enerpac HF

Buna

and Viton

21,755 psi

[1500 bar]

70 dBA Max.

21 SCFM

[113 L/Min]

54 lbs.

[32 Kg]

*

Actual air consumption will vary depending on application. Refer to Section 4.3 for additional information.

3.3

External Dimensions

A

B

C

Dimension

Inches (mm)

A

15.3 [389]

B

15.75 [400]

C

15.0 [381]

80 PSI [5,5 bar] Air Pressure

80 PSI [5,5 bar] Air Pressure

90 PSI [6,2 bar] Air Pressure

90 PSI [6,2 bar] Air Pressure

100 PSI [6,8 bar] Air Pressure

100 PSI [6,8 bar] Air Pressure

(shown for reference only – see note at bottom of graph)

(shown for reference only – see note at bottom of graph)

ATP-1500 Air-Hydraulic Pump – Flow vs. System, Pressure

F

L

O

W

FLOW

inin

33

/m

in

.

[l

/m

in

]

/min. [l/min]

Note:

Pump air relief valve is factory set at 90 psi [6,2 bar] inlet air pressure, limiting the maximum hydraulic pressure to 25,000 psi [1750 bar].
Maximum hydraulic operating pressure is 21,755 psi [1500 bar].

HYDRAULIC PRESSURE

HYDRAULIC PRESSURE

psi [bar]

psi [bar]

30

[0,49]

25

[0,40]

20

[0,32]

15

[0,24]

10

[0,16]

5

[0,08]

0

0 5000

10000

15000

20000

25000

[350]

[700]

[1050]

[1400]

[1750]