Enerpac ATP-Series User Manual
Page 3
3
3.0 SPECIFICATIONS
3.1
Performance Data
3.2 Technical Data
Temperature
Range
Oil Viscosity
Range
Hydraulic
Oil Type
(recommended)
Seal
Materials
Max Hyd.
Pressure
(operating)
Sound Level
Air
Consumption*
(typical)
Weight
(including
oil)
-20 to +140ºF
[-29 to +50ºC]
150 -165 S.U.S.
[15 - 25 C.S.T.]
Enerpac HF
Buna
and Viton
21,755 psi
[1500 bar]
70 dBA Max.
21 SCFM
[113 L/Min]
54 lbs.
[32 Kg]
*
Actual air consumption will vary depending on application. Refer to Section 4.3 for additional information.
3.3
External Dimensions
A
B
C
Dimension
Inches (mm)
A
15.3 [389]
B
15.75 [400]
C
15.0 [381]
80 PSI [5,5 bar] Air Pressure
80 PSI [5,5 bar] Air Pressure
90 PSI [6,2 bar] Air Pressure
90 PSI [6,2 bar] Air Pressure
100 PSI [6,8 bar] Air Pressure
100 PSI [6,8 bar] Air Pressure
(shown for reference only – see note at bottom of graph)
(shown for reference only – see note at bottom of graph)
ATP-1500 Air-Hydraulic Pump – Flow vs. System, Pressure
F
L
O
W
FLOW
inin
33
/m
in
.
[l
/m
in
]
/min. [l/min]
Note:
Pump air relief valve is factory set at 90 psi [6,2 bar] inlet air pressure, limiting the maximum hydraulic pressure to 25,000 psi [1750 bar].
Maximum hydraulic operating pressure is 21,755 psi [1500 bar].
HYDRAULIC PRESSURE
HYDRAULIC PRESSURE
psi [bar]
psi [bar]
30
[0,49]
25
[0,40]
20
[0,32]
15
[0,24]
10
[0,16]
5
[0,08]
0
0 5000
10000
15000
20000
25000
[350]
[700]
[1050]
[1400]
[1750]