Det-Tronics PIRECL Infrared Hydrocarbon Gas Detector PointWatch Eclipse User Manual
Page 41

F-2
95-8526
14.2
eclipse hArt MenU strUctUre
This section displays the menu trees for the Pointwatch Eclipse. The Menu tree shows the primary commands and
options available when using menu selections.
1 Device Setup
2 Gas xxxxxxx
3 PV xxx %LEL
4 PV AO xxx mA
5 PV URV xxx % LEL
1 Process Variables
2 Diag/Service
3 Basic Setup
4 Detailed Setup
5 Review
1 Reference xxxx
2 Snsr Temp xxxx
3 Operating Mode
4 Calibration
5 xmtr flt 1
6 xmtr flt 2
7 xmtr status 1
8 xmtr status 2
1 Zero Trim
2 Calibrate Sensor
3 Cal Date 12/2/2000
4 D/A Trim
1 4 mA
2 20 mA
3 Other
4 End
1 Self Test
2 Response Test
3 Reset
1 Gas xxxxxxxx
2 Conc 0.0% LEL
3 AO 4.00 mA
1 Running hrs xxxx
2 Max Temperatures
3 Min Temperatures
4 Cal Log
5 Event Log
% LEL
ppm
Vol %
1 URV 20-100% LEL
2 LRV 0% LEL
3 USL 100% LEL
4 LSL 0% LEL
1 Tag xxxxxx
2 Date: 6/30/2000
3 Descriptor
4 Message
5 Model: Eclipse
6 Write Protect xx
7 Revision #'s
8 Final Assembly #
9 Dev id xxxxxx
1 PV USL xxxx unit
2 Active xxxx
3 Reference xxxx
4 Ratio xxxx
5 Absorption xxxx%
6 Span Factor xxxxx
7 Snsr Temp xx degC
8 Vol % @ 100% LEL
9 Coefficient A
Coefficient B
Coefficient C
Coefficient D
Coefficient E
Spcl
Methane
Ethane
Propane
Ethylene
Propylene
Butane
Spare 6
Spare 7
Spare 8
1 Config Gas Alarms
2 Config Fault Out
3 Hart Output
4 Com Port
1 Password
2 Set Write Protect
3 Write Protect xx
Disable
Enable
Change Password
1 Protocol xxxxx
2 Poll Addr xxx
3 Baud Rate xxxx
4 Parity xxxx
1 EQ DIP Switch xxx
1 Poll Addr xx
2 Num Req preams x
1 Analog Fault Codes
2 Analog Code Values
1 High Alarm Level
2 High Alarm Latch
3 Low Alarm Level
4 Low Alarm Latch
Spcl Gas Coef A
Spcl Gas Coef B
Spcl Gas Coef C
Spcl Gas Coef D
Spcl Gas Coef E
Spcl Gas Vol %
1 Universal Rev 5
2 Fld Dev Rev 1
3 Software Rev xxx
Running Hrs xxxxx
Event History
(Event)
xxxxx Hrs
1 Previous
2 Next
3 Exit
Running Hrs xxxxx
Calibration History
(Event)
xxxxx Hrs
1 Previous
2 Next
3 Exit
Running Hrs xxxxx
Minimum Temperature
xxxx Deg C xxxx Hours
Min Temp Since Reset
xxxx Deg C xxxx Hours
Reset Min & Max Temp?
ABORT OK
Running Hrs xxxxx
Maximum Temperature
xxxx Deg C xxxx Hours
Max Temp Since Reset
xxxx Deg C xxxx Hours
Reset Min & Max Temp?
ABORT OK
1 Calibrate
2 Cal Conc xxxx
3 Cal Gas xxxx
4 Gas Type xxxx
5 Calib Type xxxx
6 Cuvette Length
Same
Methane
Propane
Std
Cuvette
Eclipse
PIR 9400
User Defined
1 Warm Up
2 Blocked Optics
3 Calibration
4 Fault
Modbus
ASCII
1200
2400
4800
9600
19.2K
None
Even
Odd
1 Test Device
2 Loop Test
3 Calibration
4 Status
5 History
1 Tag xxxxxx
2 PV Unit xxxxxx
3 Range Values
4 Device Information
5 Gas xxxxxxxx
1 Sensor Information
2 Gas Type xxxxx
3 Output Condition
4 Device Information
5 Write Protect
NOTE
Refer to “Alarm Relays” in the
Specifications section of this
manual for important information
regarding alarm relays.