beautypg.com

Det-Tronics PIRECL Infrared Hydrocarbon Gas Detector PointWatch Eclipse User Manual

Page 29

background image

27

95-8526

14.2

pireCl MoDel Matrix

MoDel DeSCription
pireCl
Point Infrared Eclipse Gas Detector

type

threaD type

a

3/4” nPt

b

M25

type

oUtpUt & MeaSUreMent optionS

1

4-20 ma with HaRt protocol & RS-485: 0-100% LFL Full Scale Range

4

Eagle Quantum Premier (EQP): 0-100% LFL Full Scale Range

type

optional oUtpUtS

a

HaRt Communication Port

b

HaRt Communication Port and Relay Board (not compatible with EQP)

ex d only

D

no optional outputs

e

Relay Board (not compatible with EQP)

ex d only

type

weather proteCtion

1

Weather Baffle with Hydrophobic Filter

2

Weather Baffle without Hydrophobic Filter

3

Weather Baffle with Hydrophobic Filter and 1/16” threaded Calibration Port

4

Weather Baffle without Hydrophobic Filter and 1/16” threaded Calibration Port

5

no Weather Protection Installed

type

approValS*

b

Brazil

r

Russia

S

SIL

t

SIL/FM/CSa/atEX/CE/IECEx

U

ukraine

w

FM/CSa/atEX/CE/IECEx

y

China

type

ClaSSifiCation**

1

Division/Zone Ex de

2

Division/Zone Ex d

*type “approvals” can use one or more letters.
**Detectors are always Class I, Div. 1.