iecex ApprovAl Description
The following items, functions and options describe the IECEx approval.
ApprovAl
PointWatch Eclipse
®
Infrared Hydrocarbon Gas Detector, Model PIRECL Series.
IECEx ULD 04.0002X
Ex de IIC T4-T5 Gb
-- OR --
Ex de [ib] IIC T4-T5 Gb
(with HART communication port)
T5 (Tamb –50°C to +40°C)
T4 (Tamb –50°C to +75°C)
IP66/IP67.
-- OR --
IECEx ULD 04.0002X
Ex d IIC T4-T5 Gb
-- OR --
Ex d [ib] IIC T4-T5 Gb
(with HART communication port)
T5 (Tamb –55°C to +40°C)
T4 (Tamb –55°C to +75°C)
IP66/IP67.
HART Communication Port:
Uo = 4.0V
Co = 20μF
Io = 100mA
Lo = 500μH
IEC Conditions of Certification:
•	 The	field	wiring	terminal	connections	are	certified	for	a	single	wire	in	size	from	0.2	to	2.5	mm2,	(or	two	conductors	
with same cross section 0.2 to 0.75 mm
2
). The screws must be tightened down with a torque 0.4 to 0.5 Nm.
•	 The	metal	housing	of	the	Model	PIRECL	Gas	Detector	must	be	electrically	connected	to	earth	ground.
•	 The	gas	detector	shall	be	protected	against	any	impact	greater	than	4	joules.
•	 The	intrinsically	safe	output	on	the	HART	Communicator	Port	is	internally	connected	to	frame.
•	 The	power	supply	for	the	detector	has	to	be	a	Safety	Isolating	transformer	according	to	e.g.	IEC61558.		The	rating	
of the power supply line fuse shall be less than 3.1 A.
• When connecting to a circuit using up to 1% of Co or Lo, then the C or L is limited to the Co and Lo listed above. If
either the C or L is above 1% of Co or Lo, then C or L are each limited to 50% of the Co or Lo listed above.
• Um is restricted to 250 V, prospective short circuit current < 1500 A.
IEC Standards:
IEC 60079-0: 2007
IEC 60079-1: 2007-04
IEC 60079-11: 2006
IEC 60079-7: 2006-07
IEC 60529, 2.1 Edition with Corr. 1
(2003-01 + 2 (2007-10)
WARNING
Always ensure that the detector/junction box hazardous (classified) location ratings are applicable for the 
intended use.