Det-Tronics PIRECL Infrared Hydrocarbon Gas Detector PointWatch Eclipse User Manual
Page 37

D-1
95-8526
14.2
Appendix d
iecex ApprovAl Description
The following items, functions and options describe the IECEx approval.
ApprovAl
PointWatch Eclipse
®
Infrared Hydrocarbon Gas Detector, Model PIRECL Series.
IECEx ULD 04.0002X
Ex de IIC T4-T5 Gb
-- OR --
Ex de [ib] IIC T4-T5 Gb
(with HART communication port)
T5 (Tamb –50°C to +40°C)
T4 (Tamb –50°C to +75°C)
IP66/IP67.
-- OR --
IECEx ULD 04.0002X
Ex d IIC T4-T5 Gb
-- OR --
Ex d [ib] IIC T4-T5 Gb
(with HART communication port)
T5 (Tamb –55°C to +40°C)
T4 (Tamb –55°C to +75°C)
IP66/IP67.
HART Communication Port:
Uo = 4.0V
Co = 20μF
Io = 100mA
Lo = 500μH
IEC Conditions of Certification:
• The field wiring terminal connections are certified for a single wire in size from 0.2 to 2.5 mm2, (or two conductors
with same cross section 0.2 to 0.75 mm
2
). The screws must be tightened down with a torque 0.4 to 0.5 Nm.
• The metal housing of the Model PIRECL Gas Detector must be electrically connected to earth ground.
• The gas detector shall be protected against any impact greater than 4 joules.
• The intrinsically safe output on the HART Communicator Port is internally connected to frame.
• The power supply for the detector has to be a Safety Isolating transformer according to e.g. IEC61558. The rating
of the power supply line fuse shall be less than 3.1 A.
• When connecting to a circuit using up to 1% of Co or Lo, then the C or L is limited to the Co and Lo listed above. If
either the C or L is above 1% of Co or Lo, then C or L are each limited to 50% of the Co or Lo listed above.
• Um is restricted to 250 V, prospective short circuit current < 1500 A.
IEC Standards:
IEC 60079-0: 2007
IEC 60079-1: 2007-04
IEC 60079-11: 2006
IEC 60079-7: 2006-07
IEC 60529, 2.1 Edition with Corr. 1
(2003-01 + 2 (2007-10)
WARNING
Always ensure that the detector/junction box hazardous (classified) location ratings are applicable for the
intended use.