9 config menu—total matrix reset, N 8.2.9 – Kramer Electronics VS-3232DN User Manual
Page 45
VS-3232DN - Using the Configuration Menus
41
3. Press ENT to store the current configuration as the default configuration.
The following is displayed:
current matrix stage is OKAY?
press TAKE to confirm
4. Press TAKE.
The following is displayed:
current matrix stage
store as DEFAULT setup
This indicates that the current setup is stored as the default setup. After a
few seconds the next option on the Config Menu is displayed.
8.2.9
Config Menu—Total Matrix Reset
This option lets you turn all outputs off or reset the unit to its factory default
settings.
To reset the matrix setup:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until the following is displayed:
TOTAL MATRIX RESET
exit = ESC
ENT = submenu
3. Press ENT to enter the Reset Submenu.
The following is displayed:
COMPLETELY MATRIX RESET
1:ALL outputs OFF 2:Factory default
4. Press 1 to turn off all outputs or 2 to perform a factory reset of all options.
Warning:
Selecting option 2 to perform a factory default reset
clears all setups, options and configuration
!