Table 7, Modem control parameters – Vaisala Hydromet Data Collection Platform User Manual
Page 72

User’s Guide ______________________________________________________________________
70 ___________________________________________________________________M210785EN-E
Common configuration parameters for modem controls are listed in
. All parameters may not be applicable for a certain
modem type.
The lowest part of the view provides an interface for managing modem
commands and responses. For configuration instructions, refer to
Vaisala HydroMet™ Data Collection Platform User’s Guide,
Volume 3.
Table 7
Modem Control Parameters
Parameter
Use
Command delay
Delay in milliseconds between
successive commands.
Escape delay
Delay in milliseconds between
escape characters (+) used when
closing the connection.
Dial retry count
Number of retries if opening the
connection fails.
Dial retry delay
Delay in milliseconds after a failed
connection attempt before attempting
a new connection.
Options/Reset after failure
Use power control output to reset the
device after failure.
Options/Preserve power
Keep modem powered only with
active connection.
Options/Answer incoming
Answer incoming calls.
Options/Debug output
Provide additional operation
information to COM0.
Power control
Power control component
Powering delay
Delay in milliseconds between
modem power-up and the first
command.
Carrier detect input
Optional input component used to
monitor the carrier detect signal from
the modem.
Carrier detect variable
Variable to monitor in the carrier
detect component.
Mask value for CD status
Mask logically ANDed with value of
the carrier detect variable. If not set,
value 0 = CD off, else CD ON.