Table 20, Alarms, Table 21 – Vaisala Hydromet Data Collection Platform User Manual
Page 139: Timed events, Table 20 alarms, Table 21 timed events

Chapter 4 ____________________________________________ Basic Use of Lizard Setup Software
VAISALA______________________________________________________________________ 137
Table 20
Alarms
Col # Column Label
Content
1
Name
Alarm name
2
Interval [s]
Condition test interval in seconds
3
Source
Source for the tested variable
4
Variable
Name of the tested variable
5
Target Act.
Target report or the log group when an alarm
becomes or already is active
6
Target Deact.
Target report or the log group when an alarm
becomes or already is inactive
7
Test
Alarm condition in comparison to minimum and
maximum values:
- Below min = Below minimum
- Above max = Above maximum
- Outside min - max = Between minimum and
maximum
- Between min - max = Between minimum and
maximum
8
Min
Value for the minimum limit
9
Max
Value for the maximum limit
10
Limit Source
Source for the limit when an other variable is
used as the limit
11
Limit Variable
Name of the limiting variable when an other
variable is used as the limit
Table 21
Timed Events
Col # Column Label
Content
1
Timer #
Timer number. Use this as the first parameter
intervals through the service or remote
command interface:
ctev <tevId> <interval>
2
Target
Target component name
3
Event
Triggered event type
4
Interval [s]
Triggering interval in seconds
5
Synch [s]
Synchronization time in seconds counted from
00:00:00 hours
6
Timezone
Time zone: Local or UTC (formerly Greenwich
mean time)
7
Timer type
Timer type: Periodic or Single shot