Figure 86, Intervals and synchronization times, Table 24 – Vaisala Hydromet Data Collection Platform User Manual
Page 179: Application timer parameters

Chapter 5 ________________________________________ Advanced Use of Lizard Setup Software
VAISALA______________________________________________________________________ 177
Figure 86
Intervals and Synchronization Times
Interval and synchronization times are presented in milliseconds. For
synchronization time, however, only full seconds correspond to actual
time. The milliseconds only give the order of execution for timed events
synchronized to the same second.
Table 24
Application Timer Parameters
Parameter
Use
Interval
Interval for timed events
Synchronization
time
Time after midnight to which the timer is synchronized
Timezone
Select whether the timer is tied to local time (default) or
to Coordinated Universal Time (UTC)
Type
Timer type: 0=single shot, 1=periodic
Scale
Timer scale:
0=relative to start of timing services, that is, system
startup.
1=absolute time
The following letters refer to
:
S
=
Synchronization time
I
=
Interval