Using Static Parameters with
Timers
It is often necessary to change the interval or synchronization time of
timers. You can define these to be read from static parameters. Static
parameters can also be changed at runtime by using the spset command.
First, it is recommended that you create the parameters to be used in the
Static Parameters tab of the Setup view.
0711-106
Figure 91
Setup View: Static Parameters Tab
To change an interval or synchronization, proceed as follows:
1.
Go to the Timers view.
2.
Right-click the timer to be modified either in the Interval or the
Synch time column. Select Advanced edit from the list. The Edit
Timer window opens; see
NOTE
The Measure field has to be changed to seconds. In order to change it,
double-click the measure field of the static parameter in question and
select second.