beautypg.com

Ag Leader EZ-Guide 250 Getting Started Guide User Manual

Page 12

background image

Outputting simulated radar to send speed to another agricultural device, such as a yield monitor or a
variable rate controller.

Outputting NMEA messages to an external device.

To add a serial port to the standard lightbar cable:

Do one of the following:

1.

Order the EZ−Guide 250 all−port cable (P/N 64045).

Order the serial port add−on cable (P/N 63076).

Identify P2 on the power cable (P/N 65168). It is the black 12−pin Deutsch connector.

2.

Pull out the connector wedgelock with a pair of needlenose pliers. The wedgelock is the piece of orange
plastic with four square holes.

3.

On the other side of the dust cover, remove the sealing pins from cavities 5, 6, and 7.

4.

Insert the labeled contacts on cable P/N 63076 into the specified cavities:

5.

Yellow − Cavity 5

Violet − Cavity 6

Green − Cavity 7

Replace the wedgelock.

6.

8