Real-time clock battery

A lithium-ion battery in the receiver
powers the internal real-time clock
and so enables the receiver to get a
first fix faster. The battery has a life
of 7.5 years. When the battery fails,
the internal clock cannot keep
accurate time and the receiver may
take longer to output GPS positions.

Please contact your local Ag Leader Reseller to
get the batteries replaced. You cannot replace the
battery yourself.

Factory defaults

You need to restore the receiver
factory defaults.

To restore receiver factory default settings:

1. Connect the receiver to a computer. Turn on the

receiver.

2. Run the AgRemote utility.

3. Navigate to the Clear BB RAM screen.

4. Press

2

until Yes appears.

5. Press

4.

The factory default settings are restored. The DGPS
service subscription is not lost.

Problem

Possible solution

AgRemote cannot communicate with
the receiver. All you see is a blank
screen.

1. Make sure that:

• the receiver is connected to a 12–32 V DC power

source

• all cable connections between the receiver and

the computer are secure

• you are using the correct COM port

2. Turn off the receiver then turn it on again.

3. Select File / Connect.

Problem