beautypg.com

3 maintenance and troubleshooting, Start-up problems, The library does not power on – HP ESL E-series Tape Libraries User Manual

Page 73

background image

3 Maintenance and troubleshooting

This chapter describes problems you may encounter during the setup and operation of the library.

Corrective information is provided to help you resolve the problems. The information is organized into:

Start-up problems
OCP problems
Robotics problems
Operating problems
Switch problems
Tape drive problems
Interface Manager card problems
FC interface controller problems
Maintaining tape cartridges
Cleaning tape drives

NOTE:

Also see

Sense data values

for information on values appearing in library error codes and the

error log.

Start-up problems

This section describes corrective actions for problems which occur during start-up.

The library does not power on

Verify that:

The power cord is connected to a grounded electrical outlet.

The power distribution unit’s two breaker switches are on (left rear corner of cabinet).

The power supply switches are on.

The power switch behind the service tray is on. (Your library might not have a service tray.)

The library or tape drives are not detected by the Interface Manager or

Command View TL software

Verify cable connections and termination.

Verify the cabling.

Verify that the drives and library are powered on and ready.

Ensure that the interface controllers are powered on and ready.

During initialization, the library reports “not ready”

Determine the failure type by checking any previous error codes returned to the host computer, or

by getting a library support ticket.

Correct the cause of the error.

HP StorageWorks