HP ESL E-series Tape Libraries User Manual
Page 115

Sense
key
ASC
ASCQ Message name / description
4
84
See
VERTICAL HARDWARE FAILURE
•
Remove any obstructions.
•
Run the Robotics Self Test from the OCP.
4
85
See
HORIZONTAL HARDWARE FAILURE
•
Remove any obstructions.
•
Run the Robotics Self Test from the OCP.
4
87
See
DEPTH HARDWARE FAILURE
•
Remove any obstructions.
•
Run the Robotics Self Test from the OCP.
4
88
00
WARNING SAFE TEMPERATURE EXCEEDED
This is a warning that the temperature in the library exceeds the normal
operational temperature 40
o
C (104
o
F).
4
88
01
MAXIMUM TEMPERATURE EXCEEDED
The robot in the overheated cabinet turns off and remains off until the
temperature returns to an acceptable level. For LTO, the acceptable level
is 52
o
C (127
o
F); for SDLT, the acceptable level is 49
o
C (120
o
F).
•
Check whether the air filters need to be replaced.
•
Check for fan failure.
•
Lower the ambient temperature.
4
89
00–FF
VISION HARDWARE FAILURE
Vision internal failure.
4
8A
02
CALIBRATION FAILURE
Check slots, cartridges, targets, and all internal elements. Verify that the
panels are properly seated and that doors are closed.
4
8B
See
CLM HARDWARE FAILURE
CLM failure.
4
8C
06
LOAD PORT DOOR OPEN
Load port door unlocked but failed to open.
4
8E
02
SCSI UPGRADE TRANSFER FAILED
A data transfer error or a data storage error was received during the
firmware upgrade.
4
8E
03
CABINET CONTROLLER UNABLE TO UPLOAD
Unable to upload firmware to the cabinet controller.
•
Retry the download.
•
Check cable connections.
•
Replace Smart Media and retry.
4
8E
04
ROBOTICS CONTROLLER UNABLE TO UPLOAD
Unable to upload firmware to the robotic controller. Verify that the
firmware image is correct and attempt to update again.
4
F2
00
I2C BUS COMMUNICATION FAILURE
Unable to communicate with the drive cluster.
•
Check I2C cable connection on the drive cluster.
•
Check that the cluster is powered on.
•
Check the LED status of the cluster controller.