Sense
key
ASC
ASCQ Message name / description
5
81
F0
PICKER INVALID COMMAND
Picker hardware commanded to position out of system mechanical limits.
Run the Robotics to Home Position test from the OCP.
5
82
E0
ROTARY INVALID START CONDITION
Rotary hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
5
82
F0
ROTARY INVALID COMMAND
Rotary axis was commanded to a position out of its legal range. This
is an internal code failure.
•
Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
•
Verify that the library and its components have the current firmware.
5
83
E0
EXTENSION INVALID START CONDITION
Extension hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
5
83
F0
EXTENSION INVALID COMMAND
Extension hardware was commanded to a position out of the systems
mechanical limits.
•
Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
•
Verify that the library and its components have the current firmware.
5
84
E0
VERTICAL INVALID START CONDITION
Vertical hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
5
84
F0
VERTICAL INVALID COMMAND
Vertical hardware commanded to position out of system mechanical
limits.
•
Run the Robotics to Home Position test from the OCP.
•
If the problem persists, calibrate the library.
•
Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
•
Verify that the library and its components have the current firmware.
5
85
E0
HORIZONTAL INVALID START CONDITION
Horizontal hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
5
85
F0
HORIZONTAL INVALID COMMAND
Horizontal hardware commanded to position out of system mechanical
limits.
•
Run the Robotics to Home Position test from the OCP.
•
If the problem persists, calibrate the library.
•
Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
•
Verify that the library and its components have the current firmware.
5
87
F0
DEPTH INVALID START CONDITION
Depth hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.
118
Sense data values