beautypg.com

HP ESL E-series Tape Libraries User Manual

Page 114

background image

Sense

key

ASC

ASCQ Message name / description

2

80

01

DRIVE CLEAN REQUIRED.
A tape drive requires cleaning.

2

80

07

SYSTEM IS STOPPED
The STOP button on the control panel was pressed. Press the STOP

button again to start the library.

2

80

09

LOGICAL UNIT IS TURNED OFF-LINE
Through the Operations menu on the OCP, bring the library on-line.

2

3B

11

MAGAZINE NOT ACCESSIBLE
The tape cartridge magazine can not be accessed.

2

3B

12

MAGAZINE NOT PRESENT
The tape cartridge magazine is not present.

2

5A

01

OPERATOR MEDIUM REMOVAL REQUEST
Indicates that an element contains a cleaning cartridge that is “used-up”

and the library is unable to export the cleaning cartridge. Manually

unload the tape. The load port door is open, so import/export elements

can not be accessed.

3

52

00

DRIVE REPORTING MEDIA ERROR
The tape drive is indicating that it has detected a problem with the

media.

The tape in question should be removed from the library and

discarded.

Check drive logs for more information.

4

44

00

INTERNAL FAILURE

4

80

11

MOTOR POWER FAILURE
Indicates motor powered off for a reason not otherwise reported. Check

the cabinet controller and the umbilical. Check the 55V LED on the

picker to determine whether this is the motor that failed. Verify that the

doors are closed. Check the door sensors.

4

80

23

BAR CODE SCANNER FAILURE
Bar code scanner has failed. Run the Robotics to Home Position test

from the OCP. Run Calibrate Cabinet Test from the OCP and inventory

the cabinet.

4

80

0A

CONFIGURATION SETTINGS CORRUPTED
Reconfigure the library. Run the Calibrate Cabinet Test from the OCP.

4

80

0F

LOW POWER ERROR
Check power connections and power supplies.

4

81

See

Table

22

PICKER HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

4

82

See

Table

22

ROTARY HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

4

83

See

Table

22

EXTENSION HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

114

Sense data values