Sense
key
ASC
ASCQ Message name / description
5
8B
F0
CLM INVALID COMMAND
CLM hardware commanded to position out of system mechanical limits.
•
Run the Robotics to Home Position test.
•
If the problem persists, calibrate the library.
6
2B
01
IMPORT OR EXPORT ELEMENT ACCESSED
Load port door has been closed.
6
29
00
POWER-ON, RESET OR BUS DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
6
29
01
POWER-ON RESET OCCURRED.
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
6
29
02
BUS RESET OCCURRED.
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
6
29
03
BUS DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
6
29
04
INTERNAL DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
6
80
00
DOOR WAS OPENED INVENTORY MAY HAVE BEEN CORRUPTED
Close door and retry command after inventory is complete.
6
80
07
SYSTEM STOP BUTTON WAS PRESSED
The STOP button on the control panel was pressed. Press the STOP
button again to start the cabinet. Retry command.
6
80
09
LOGICAL UNIT TURNED ON-LINE
Through the menu options, bring the library on-line. This message is
informational only; no action is required.
6
80
09
LOGICAL UNIT TAKEN OFFLINE
Library was taken off-line through the remote web management or OCP.
6
80
0E
DATA TRANSFER CHANGED
A drive has been inserted/removed into the system. Use “Read Element
Status” to determine status of drives.
6
2A
01
MODE PARAMETERS CHANGED
Mode parameters may have changed due to another host issuing a
Mode Select command.
6
3B
13
MAGAZINE INSERTED
A tape cartridge magazine has been inserted.
B
08
00
LOGICAL UNIT COMMUNICATION FAILURE
Check cables. Ensure library unit is powered on. Retry command.
B
08
01
LIBRARY COMMUNICATION TIME-OUT
Internal communications not responding. Retry command. Check the
following internal cable connections: Ethernet cable, umbilical cable,
robotics controller, cabinet controller.
120