Managing fabrics

Entries in the Event Browser shown in

Figure 21

are formatted by severity, time stamp, source, type, and

description. The maximum number of entries allowed in the Event Browser is 10,000. The maximum

number of entries allowed on a switch is 1200. Once the maximum is reached, the event list wraps and

the oldest events are discarded and replaced with the new events. Event entries from the switch, use the

switch time stamp, while event entries generated by the application have a workstation time stamp. You

can filter, sort, and export the contents of the Event Browser to a file. The Event Browser begins recording

when enabled and switch management application is running.

Figure 21

Event Browser

Severity is indicated in the severity column using icons as described in

Table 5

.

Table 5

Severity levels

Severity icon

Description
Alarm — an alarm is a "serviceable event". This means that attention by

the user or field service is required. Alarms are posted asynchronously to

the screen and cannot be turned off. If the alarm denotes that a system

error has occurred the customer and/or field representative will generally

be directed to provide a "show support" capture of the switch.
Critical event — an event that indicates a potential failure. Critical log

messages are events that warrant notice by the user. By default, these log

messages will be posted to the screen. Critical log messages do not have

alarm status as they require no immediate attention from a user or service

representative.
Warning event — an event that indicates errors or other conditions that

may require attention to maintain maximum performance. Warning

messages will not be posted to the screen unless the log is configured to

do so. Warning messages are not disruptive and, therefore, do not meet

the criteria of Critical. The user need not be informed asynchronously

No icon

Informative — an unclassified event that provides supporting information

Column sorting

buttons

Severity

column