beautypg.com

HP XP P9500 Storage User Manual

Page 82

background image

S-VOL access

P-VOL
access

Description

BCM status

RWC status

continues beyond the backup time for the nonvolatile
memory.

SUSPER (50): The pair was split because data mismatch
between P-VOL and S-VOL during initial copy operation.
The cause of the error is invalid track format.

See also

“Suspend types” (page 83)

.

No

Read/Write

The pair is in transition to Suspend by user or Suspend by
system status.

TRANS (60)

Suspending

No

Read/Write

The pair relationship is being released. When the operation
completes, status changes to Simplex.

TRANS (61)

Deleting
(releasing)

Read Only if
Mode=20 is

Read/Write

HOLD (70)

Hold

The pair or command devices are ready for the delta
resync operation. Incoming write data for the Cnt Ac-S
Z S-VOL is stored in the master journal volume.

ON, otherwise
No.

Operations allowed:

- Delta resync

- Pair-delete

- Change pair options

-

Read/Write

Pair status is changing to Hold so that the delta resync pair
can be created.

HOLDTRNS (72)

Holding

Operations allowed on pairs in Holding status:

Delta resync operation

Pair release

Change pair options

If the delta resync operation is run on a pair in Holding
status, the operation could fail. If you specify Entire for the
delta resync Failure field on the Change Journal Option
dialog box, differential data is copied to an S-VOL.

-

-

Differential data cannot be retained as a journal because
of a hardware error.

HOLDER (71)

(No parallel
RWC status)

-

-

Although the user performed a resync, the delta resync
cannot be run, and thus differential data cannot be retained
as a journal.

HOLDER (73)

(No parallel
RWC status)

82