Add pair dialog box – HP XP P9500 Storage User Manual
Page 173

Description
Item
configuration, if a mirror configured to the S-VOL is also the mirror for the delta resync
operation, the write operation cannot be performed even if Enabled is specified.
Note that if Cnt Ac-J and Cnt Ac-J Z pair volumes are registered in the same consistency
group, Enabled(Not Received) displays even if write I/O data from the host has been
received.
•
Disabled—the write operation to the S-VOL is not allowed.
May list the following:
Other Information
•
Paired Time, which is the date and time when the volume pair was created.
•
Updated Time, which is the date and time when the volume pair status was last updated.
•
EstablishedTime, which is the date and time when the volume pair was created.
•
Updated Time, which is the date and time when the volume pair status was last updated.
•
Displays Reverse Resync if reverse resync is performed on the pair. Otherwise, displays
nothing.
•
Consistency Time, the time stamp transferred by the host computer if the S-VOL uses the
system timer.
If the pair is split and the consistency time for the S-VOL does not match the consistency
time for the journal, displays the phrase differs from C/T of the Journal.
•
Timer Type, the type of timer used by the data volume:
- System—the system clock of the mainframe host is used.
- Local—the system clock of the SVP is used.
- None—no system clock is used, the SVP time is used.
•
SEQCHK displays if the S-VOL uses the system timer and receives update data without time
stamp from the host computer.
When clicked, the Pair Operation window refreshes when it re-displays.
Refresh the Pair
Operation window
after this window is
closed
Add Pair dialog box
Use this dialog box to create a pair.
See
“Creating the initial copy ” (page 68)
for complete information.
Pair Operation window
173