Troubleshooting logical paths
Troubleshooting information for logical paths between storage systems is shown below.
Corrective action
Description
Path status
None required.
This path has been
successfully established and
Normal
can be used for Cnt Ac-J Z
copy activities.
The link initialization
procedure to the secondary
Initialization Failed
•
Make sure that the primary and secondary systems are physically
and correctly connected.
system failed because the
•
Make sure that you entered the correct secondary system S/N,
Controller ID, and primary and secondary system port numbers.
physical path connection was
missing between the primary
and secondary systems.
•
Make sure the primary and secondary system ports are configured
correctly.
Communication between the
primary and secondary
system timed out.
Communication Time Out
•
Make sure the secondary system is powered on and that NVS and
cache are fully functional.
•
Make sure that network relay devices are properly configured and
functional. This includes cables, connectors, switches, extender
devices, communication lines, and all other devices connected to
the extenders.
The primary system rejected
the logical path link control
Port Rejected
•
Delete all paths and RCUs not in use.
•
Make sure that all primary and secondary system ports are properly
configured: ordinary RCU target ports for secondary systems,
function because all logical
path resources in the primary
initiator ports for primary systems. If necessary, connect to the
secondary system to delete paths.
system are being used for
other connections.
•
Reconfigure the ports, then add the paths and RCUs to the MCU
again.
Follow the same corrective actions in Port Rejected.
The secondary system
rejected the logical path link
Pair-Port rejected
control function because all
logical path resources in the
secondary system are being
used for other connections.