HP XP P9500 Storage User Manual
Page 127

Description
Error code (SSB2)
•
Cnt Ac-J Z P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is being used as Business
Copy Z P-VOL.
•
Cnt Ac-J Z P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is the source volume of
Auto LUN.
•
Cnt Ac-J Z P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is being used as Fast
Snap or Snapshot P-VOL.
The command was rejected because the emulation type of the specified S-VOL was unsupported.
EB7F
The command was rejected because the specified volume was the V-VOL or the pool-VOL. Please
check the status of the volume.
EB80
The command was rejected because the path from the secondary system to the primary system
was not set, or the S-VOL was in the Simplex status.
EB87
The command was rejected because of one of the following:
EB88
•
The specified S-VOL was being used as a Business Copy Z S-VOL.
•
The specified S-VOL was Not Ready, which means that the hard disk drive cannot be used.
The command was rejected because the emulation types of the specified P-VOL and S-VOL were
not the same.
EB89
The command was rejected because the emulation types of the specified master journal and the
restore journal were not the same.
EB8A
The command was rejected because the LUSE configuration of the P-VOL is different from the
LUSE configuration of S-VOL.
EB8E
The command was rejected because the specified pair could not transit the status.
EB94
The pair creation command was rejected because the specified S-VOL was not mounted on the
secondary system.
EB9F
The pair operation command was rejected because the specified S-VOL was not mounted on the
secondary system.
EBA0
The command was rejected because the volume specified for the secondary volume was in either
one of the following status.
EBA7
•
Increasing the capacity by Thin Provisioning Z.
•
Releasing the page of Thin Provisioning Z.
•
Initializing the pool of Thin Provisioning Z.
The command was rejected because the license capacity of the Data Retention in the secondary
system exceeds the setting value. Please check the license capacity setting for Data Retention in
the secondary system.
EBAF
The command was rejected because the specified Cnt Ac-J Z S-VOL was used by either Business
Copy Z or Compatible FlashCopy.
EBC6
The command was rejected because the journal restore operation is in progress in the Cnt Ac-J
Z pair through another mirror ID.
EBCA
•
If the Cnt Ac-J Z pair with another mirror ID is in Suspending status, re-issue the request when
the pair status is changed to the Suspend status.
•
If the Cnt Ac-J Z pair with another mirror ID is in the Duplex status, reissue the request after
awhile.
The command was rejected because un-updated differential data exists in the specified S-VOL.
EBCE
The Cnt Ac-J Z Pairresync (journal resync mode that forcibly copies all data) was received because
of the Cnt Ac-J Z Pairresync (delta resync) failed. The command was rejected because the Cnt
Ac-J Z pair was not in HOLD status.
EBCF
Troubleshooting with RAID Manager
127