Description

Error code (SSB2)

The command was rejected because the specified secondary journal was not in the Stopped
status.

EA1C

The command was rejected because the request was received for the S-VOL as the P-VOL.

EA1E

The command was rejected because the request was received for the P-VOL as the S-VOL.

EA20

The command was rejected because the state of journal was not Stopped.

EA22

The command was rejected because the state of S-VOL was not SSWS.

EA25

The command was rejected because the state of master journal was other than Active or Stopped.

EA29

The command was rejected because the state of restore journal was other than Active or Stopped.

EA2C

The command was rejected because the state of mater journal was other than Active.

EA33

The command was rejected because the state of restore journal was other than Active.

EA36

The command was rejected because the specified S-VOL was in the state of status transition.

EA3A

The command was rejected because the specified S-VOL was in the state of Suspending.

EA3B

The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's program product.

EA40

The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's program product.

EA41

The command was rejected because the specified volume is used in the system that consists of
multiple primary and secondary systems.

EA8B

The command was rejected because the microcode was being replaced.

EA92

The command was rejected because the volume specified for the P-VOL was initializing the pool
of Thin Provisioning Z.

EA95

The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's Cnt Ac-J Z. Check the license capacity as well as the related program
product.

EAA2

The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Continuous Access Synchronous Z. Check the License capacity as well
as the related Program product.

EAA3

The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Cnt Ac-J Z. Check the license capacity as well as the related program
product.

EAA5

The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's Continuous Access Synchronous Z. Check the license capacity as well as
the related program product.

EAA6

The paircreate operation failed because the primary system’s differential management area had
no free space.

EAB6

If no extended shared memory is installed in the primary system, install it and repeat the operation.

If extended shared memory is installed, the number of pairs that can be created in the system is
exceeded.

The paircreate operation failed because no extended shared memory is installed in the primary
system. Install extended shared memory in the primary system and then repeat the operation.

EAB7

The paircreate operation failed because the secondary system’s differential management area
had no free space.

EAB8

If no extended shared memory is installed in the secondary system, install it and repeat the
operation.

If extended shared memory is installed, the number of pairs that can be created in the system is
exceeded.

124