HP Storage Mirroring V5.1 Software User Manual
Page 29
2 - 8
7.
Run one of the following case-sensitive commands from the temporary directory, depending
on if you have
setup.exe
or
setup_xxxx.exe
where
xxxx
is a four digit build number.
setup /s /v"DTSETUPINI=\"c:\dtinstall\DTSetup.ini\" /qn"
setup_xxxx /s /v"DTSETUPINI=\"c:\dtinstall\DTSetup.ini\" /qn"
Remote, automatic Storage Mirroring installation or Upgrade
1.
Create a temporary directory on the primary site server. For example, create z:\dtinstall.
2.
Share the temporary folder.
3.
On the CD, locate the files in a subdirectory under \DblTake that is appropriate for your
architecture, either i386, x64, or IA64. Copy the files from that subdirectory to the
temporary directory.
4.
From a command prompt, remove the read-only attributes from the files in the temporary
directory by using the command
attrib *.* -r
.
5.
Make a backup copy of the default DTSetup.ini file in the shared folder.
6.
Edit DTSetup.ini as needed using the values described in the previous tables.
7.
From each server where you want to install Storage Mirroring, map a drive to the temporary
directory that you created in step 1. For example, you might map your
m:
drive to the share.
8.
Determine the exact file name of your setup file by using the command
dir setup*.*
from
the mapped drive command prompt. Depending on how you received your software (CD or
web), your setup file name will be named
setup.exe
or
setup_xxxx.exe
where
xxxx
is
four numbers that specfy the build number. For example, your setup file might be called
setup.exe
or
setup_1352.exe
.
9.
Run one of the following case-sensitive commands from the mapped drive, depending on if
you have
setup.exe
or
setup_xxxx.exe
where
xxxx
is a four digit build number.
setup /s /v"DTSETUPINI=\"m:\DTSetup.ini\" /qn"
setup_xxxx /s /v"DTSETUPINI=\"m:\DTSetup.ini\" /qn"
NOTE:
The command must be run from the directory where the temporary files are
located as well as specifying that directory for the
.ini
file.
Spacing is critical with this command. A space should precede
/s
,
/v
, and
/qn
but should not appear anywhere else for the command to work correctly.
NOTE:
The command must be run from the shared folder as well as specifying that
directory for the
.ini
file.
Substitute your mapped drive for
m:\
.
Spacing is critical with this command. A space should precede
/s
,
/v
, and
/qn
but should not appear anywhere else for the command to work correctly.
C:\>net use m: \\server_name\share
The command completed successfully
C:\>M:
M:\>setup_1352 /s /v"DTSETUPINI=\"m:\DTSetup.ini\" /qn"