beautypg.com

Pp-32 – Acme PP-32 User Manual

Page 85

background image

85

PP-32

KOOLMASTER PP-32

REV.01

RH set point % 65

Mist shutoff % Off

Heater On time Off

Heater Off time 0

full On-Time when the humidity is at or above RH Set Point + 10% as

shown below. The cycle time can be adjusted from 0 to 900 seconds.

Set the dipswitch #6 to ON to use this function.

Set the function to "18.RH Compensation" from the main menu

using the navigation buttons then press the right-arrow key. Note

that this menu only appears if the relative humidity sensor has been

enabled during the installation setup (see sec. 5.14.3).

Use the navigation buttons in order to select the "Heater On time"

display. Note that this menu only appears if dipswitch #6 is turned

ON.

Use the adjustment buttons to set

the Heater's On-Time to the desired

value.

Press the down-arrow key once to

select the "Heater Off time" display.

Use the adjustment buttons to set the Heater's Off-Time to the

desired value.