5.12 HISTORY

5.12.1 Resetting Histories

The controller automatically resets all sensor histories when the animal

age goes from "

Off" to "1day". Note that this reset doen't clear the

Alarm Log history.

The following procedure shows how to clear all histories without having

to change the animal age.

Set the function to "12.Animal Age" from the main menu using the

navigation buttons.

Press the down-arrow key once to select the "Clear All?" menu.

If the following step is performed from the INSTALLER

mode, the Alarm Log will be lost. If it is performed from

the USER mode, the Alarm history will not be reset. Refer

to section 5.14.3 to select the proper mode.

Press

to select

Yes. The

answer is validated after a 10

second delay. The display then

returns to

"No". Histories are now

cleared.

5.12.2 Average Temperature History

The controller has an history in which the minimum and maximum

average temperature readings for the past 60 days are logged in.

Set the function to "2. Average Temp." from the main menu using

the navigation buttons then press the right-arrow key. The current

average room temperature is displayed.

Press the down-arrow key to scroll

the menus. The minimum

(T°L) and

maximum

(T°H) temperatures for

the past 60 days are displayed.

5 days ago

T°L 72.3 T°H 74.0

6 days ago

T°L 72.0 T°H 74.3

Animal Age Off

Clear All? No

!