GROUPS OF STATIC PRESSURE SET POINTS :

Two groups of static pressure set points can be defined. HI and LO static

pressure set points #2 start being used either when a certain ventilation

stage is reached or when the outside temperature decreases below a

user-define value. The following graphs sum both cases:

1. Static pressure set points' transition according to ventilation stages:

Example: when the start temperature of stage 5 is reached, the vent

doors start operating according to the second group of static

pressure set points. The first group of set points is being used

once again when the room temperature drops below the stage

5 stop temperature.

Refer to the installation setup section to activate the second group of

static pressure set points (see sec. 5.14.3).

STATIC PRESSURE SET POINTS

INFLUENCED BY VENTILATION STAGES

ROOM

TEMPERATURE

STATIC

PRESSURE

SET POINTS

LO SET POINT 1

(CLOSE AT)

LO SET POINT 2

(CLOSE AT)

FAN STAGE 5

START T°

FAN STAGE 5

STOP T°

HI SET POINT 1

(OPEN AT)

HI SET POINT 2

(OPEN AT)