6 information – NORD Drivesystems BU0135 User Manual
Page 72
SK 105E…175E Motor Starter Manual
72
Pre-series version
BU 0135 GB-2713
5.1.6
Information
Parameter
{ Factory setting }
Setting value / Description / Note
READ
RAM
READ /
FLASH
FLASH
P700
[-01]
...
[-03]
Present op. status
(Present operating status)
x
0.0 ... 21.4
Display of current messages for the present operating status of the motor starter such as errors,
warnings or the reason why switch-on is disabled. For details of messages see Section 6
[-01] = Present fault, shows the currently active (unacknowledged) fault (Section 6.2).
[-02] = Current warning, shows any current warning message (Section 6.3)
[-03] = Reason for disabled starting, indicates the reason for an active start disable (Section 6.4).
Note
SimpleBox: with the Simplebox only warning messages and faults can be displayed. Display of
the messages is encoded. For the description of the codes (warning/error numbers), please
refer to the tables in Sections Error! Reference source not found.and 6.3
ParameterBox: with the ParameterBox the messages are displayed in plain text.. In addition,
the reason for a possible disabling of starting can also be displayed.
P707
[-01]
...
[-03]
Software version
(Software version/ revision)
x
0.0 ... 9999.9
This parameter shows the software and
revision numbers in the motor starter. This
can be significant when different motor
starters are assigned the same settings.
Array [-03] provides information about any
special versions of the hardware or
software A zero stands for the standard
version.
[-01] = Software version, version number (V1.0)
[-02] = Software revision, Revision number (R1)
[-03] = Special version, of the hardware/
software (0.0)
P708
Digital input status
(Status of digital input)
x
00000 ... 11111
(bin)
or
0000 ...007F
(hex)
Displays the status of the digital inputs in binary/hexadecimal code. This display can be used to
check the input signals.
Bit 0 = Digital input 1
Bit 1 = Digital input 2
Bit 2 = Thermistor input
Bit 3 = AS-i In Bit 0
(only SK 145E…175E)
Bit 4 = AS-i In Bit 1
(only SK 145E…175E)
Bit 5 = AS-i In Bit 2
(only SK 145E…175E)
Bit 6 = AS-i In Bit 3
(only SK 145E…175E)
Bits 7-4
Bits 3-0
Minimum value
0000
0
0000
0
Binary
hex
Maximum value
0111
7
1111
F
Binary
hex
SimpleBox: The binary Bits are converted into a hexadecimal value and displayed.
ParameterBox: The Bits are displayed with increasing values from right to left (binary).