4 Commissioning
BU 0135 GB-2713
Pre-series version
45
4.2.2
Configuration
Most cases can be catered for directly via the functions of potentiometers P1 ... P4 as well as DIP switch
S1. For extended functions or for diagnostic purposes it may be necessary to adjust or view individual
parameters.
The use of a ParameterBox (SK CSX-3H / SK PAR) or NORD CON software is necessary to change the
parameters. The most important parameters are listed below:
Parameter group
Parameter numbers
Functions
Comments
Motor data
P203
Rated current of motor
Usually value from P1
P210
Start phase section for
devices with soft start
Usually the value from P3
Basic parameters
P102 … P103
Acceleration and deceleration
time for
devices with soft start
Usually the value from P4
P108
Switch-off mode for
devices with soft start
Usually the value from S1
P130
Parameter source
Potentiometer / DIP switch or
parameter
Control terminals
P420, P434
Digital inputs and outputs
Usually a fixed function
Additional parameters
P570
Locking time for reverse starting
Usually the value from P2
Information
P700
Present error