SK 105E…175E Motor Starter Manual

48

Pre-series version

BU 0135 GB-2713

4.2.2.3

SK 1x5E – Minimal configuration

All SK 1x5E models can be operated as delivered. The PTC input must be bypassed, if a motor with PTC is
not available. Parameter (P428) must be changed or DIP switch 1 must be set if an automatic startup with
"Mains On" is required.

The motor starter must be provided with a 24V control voltage.

Function

Setting

Setpoint

Integrated potentiometer P1

Frequency ramp

Integrated potentiometer P2

Controller enable

External switch S1

Motor starters

SK 105E-….

Motor starters

SK 1x5E

-

...

44

40

.

.

21

22

.

38

39

L1

-

L2/N

-

L3

115/230/400V

24V=

GND

3~ 200V…500V + PE

Switch S1

Motor PTC