2 details of the sk 1x5e control connections – NORD Drivesystems BU0135 User Manual
Page 30

SK 105E…175E Motor Starter Manual
30
Pre-series version
BU 0135 GB-2713
2.6.2
Details of the SK 1x5E control connections
Control voltage 24V external! Terminal 44. If the motor starter is not equipped with an optional mains unit it
must be supplied with an external 24V voltage.
For devices with which the AS interface is used, the supply voltage can be taken from the AS interface cable
if the appropriate jumpers are set ("only yellow cable"). Otherwise the device can also have a separate
supply ("black and yellow cable"). In this case, the jumpers must not be set.
Terminal/
Name
Function
{Factory setting}
Data
Description /
wiring suggestion
Parameter
SK 105E…SK175E
44
VI 24V
24V supply
Input
24VDC ±25%
50mA (Starter without
accessories) ... 400mA
according to load on the
inputs and outputs or
equipment with options
Connection of the supply voltage
for the control unit and supply to
outputs DOUT1+2 as well as any
connected initiators
-
40 GND / 0V
Reference potential
for digital signals
-
21
DIN1
Digital input 1
{ON right}
Digital input as per
EN 61131-2, Type 1
Low: 0-5V
(~ 9.5k
Ω)
High: 15-30V
(~ 2.5-3.5k
Ω)
Input capacitance: 10nF
Scanning time: 1ms
Reaction time:
≥ 4ms
For control of the device from an
external control unit or switch.
P420 [01]
22
DIN2
Digital input 2
{ON left}
P420 [02]
1
DOUT1
Output 1
{Error}
Digital output
18-30V, each to VI 24V
max. 200mA
Devices with AS-I
(SK 145E or higher):
Total current 165 mA
max. 100k
Wload
For evaluation in a control system.
P434 [01]
3
DOUT2
Output 1
{Starter running}
P434 [02]
38
TF+
PTC resistor input
-
For monitoring the motor
temperature by PTC.
-
39
TF-
PTC resistor input
79
MB+
Brake control
Voltage:
Mains
brake
230V
105V=
400V~
180V=
460/480V~
205V=
Current: max. 0.5A
The motor starter generates an
output voltage on Terminals
MB+/MB- for control of an
electromagnetic brake. This
depends on the supply voltage to
the SK 1x5E.
It is essential to take the correct
brake coil voltage into account in
the selection.
P107,
P114,
80
MB-
Brake control