5 Parameterisation
BU 0135 GB-2713
Pre-series version
65
RUN
MBR
U
mot
[P216]
P4 /
[P103]
P4 /
[P102]
P3 /
[P210]
[P215]
RUN
MBR
U
mot
[P216]
P4 /
[P102]
P3 /
[P210]
[P215]
RUN
MBR
U
mot
P4 /
[P103]
P4 /
[P102]
P3 /
[P210]
[P215]
[P216]
RUN
MBR
U
mot
P4 /
[P103]
P4 /
[P102]
P3 /
[P210]
[P215]
[P216]
Operating behaviour in switch-off mode 1:
In this mode, after switch-on, the torque
value (voltage) which is determined by
potentiometer 3 or P210 is applied to
the motor. The voltage is continually in-
creased during the time which is set by
potentiometer 4 or P102, until the full
voltage is reached. On enabling, the
electromechanical brake is released.
When the enabling is removed, the volt-
age is continually reduced from 100% to
0% over the period which is determined
by P4 or P103. The brake is applied af-
ter the ramp has elapsed.
Operating behaviour in switch-off mode 2:
In switch-off mode 2, the drive behaves
in the same way as in switch-off mode 1
when it is switched on. However, when
the enabling is removed, the voltage is
directly reduced to the value determined
by potentiometer 3 or P210, and then
reduced to zero within the time which is
determined by potentiometer 4 or P103.
Once again, the brake is applied after
the time has elapsed.
Operating behaviour in switch-off mode 3:
In this operating mode, the behaviour
on switch-on is identical to that in
switch-off mode 1. However, when the
enabling is removed, the motor switches
off immediately and the brake is also
applied immediately.
Operating behaviour in switch-off mode 4:
As for operating mode 3, however the
brake is applied with a delay, which is
determined by the value from potenti-
ometer 4 / P107.