beautypg.com

KYORITSU 6305 Instruction Manual User Manual

Page 38

background image

4.11

KEW6305

1 5 0 V 3 0 0 V 6 0 0 V

1 P 2 W 1 P 3 W 3 P 3 W 3 P 4 W

5 A

1 0 A

2 0 A

5 0 A

1 0 0 A 2 0 0 A 5 0 0 A 1 0 0 0 A

Setting 09” Recording interval

Following explains how to set the recording interval for integration/ demand measurement.

The recording interval is a time distance to record each measurement data into SD Card or internal

memory.

Setting time

1 / 2 / 5 / 10 / 15 / 20 / 30 sec.,
1 / 2 / 5 / 10 / 15 / 20 / 30 min.,
1 hour

Default value (or after system reset)

30 min.

1 Use the

Cursor

key on the selection screen, and select “Setting 09”.

2 Press the

ENTER

key to get the instrument into setting change mode.

3 Previous setting (or default value: 30 min.) blinks. Press the

Cursor

key to select any desired time,

and then press the

ENTER

key after making necessary change.

NOTE:

* Selectable interval is limited by the setting done at Setting 16 (Demand measurement cycle).

- An interval greater than the value set at Setting 16 cannot be selected.

- The interval should be divisible by the value set at Setting 16.

- Any of above interval is selectable if “NO” is selected at Setting 16.

Hour Minute

Second