2 limitation of saving, 5 o – 0 0 1 . kew, File name – KYORITSU 6305 Instruction Manual User Manual
Page 110

8.13
KEW6305
1 5 0 V 3 0 0 V 6 0 0 V
1 P2 W 1 P3 W 3 P 3 W 3 P4 W
5 A
1 0 A
2 0 A
5 0 A
1 0 0 A 2 0 0 A 5 0 0 A 1 0 0 0 A
8.6.2 Limitation of saving
● Limitation of saving (before starting a survey)
In the following cases, a survey cannot be started (manually or automatically) by pressing the
START/STOP
key.
< In case data is saved to SD card >
* When 511 files have been saved to the SD card;
mark appears and further data cannot be
saved.
Some files can to be deleted via the PC, otherwise all the saved files in the SD card can be deleted
using “Setting 19” of Section 4 in this manual.
< In case the data is saved to internal memory >
* When 4 files have been saved to the internal memory;
mark appears and further data
cannot be saved.
● Limitations of saving (during a survey)
When the capacity of SD card or internal memory has been exceeded during a survey; measurement
continues but
mark appears on the display screen and further data will not be saved.
Press the
START/STOP
key 2 sec. or more and stop the survey once.
Refer to preceding page and delete the unnecessary file.
● File format and name
Measured data is saved in KEW format, and the file name is assigned automatically.
File name :
5 O – 0 0 1 . KEW
1: Manual saving
2: Auto-saving (using Timer function)
Fixed no.
SD: SD card
ME: Internal memory
File no. (001 – 999)