4 demand measurement, 5 other specifications, 4 demand measurement ( demand range) – KYORITSU 6305 Instruction Manual User Manual
Page 134: Σ= σ demi dem, Tdem σ

13.5
KEW6305
Duration of integration
Displayed item
00:00:00 (hour: minute: second)
Display range
00:00:00 (0 sec.) - 99:59:59 (99-hour 59-min 59-sec)
to 000100 - 999999 (999999-hour)
*Display changes as above.
13.4 Demand measurement (
DEMAND
Range)
(1)
Target value (T
DEM
)
Display range
Preset value will be displayed and not vary. (0.1W - 999.9GW)
(2)
Predicted value (G
DEM
)
Display range
Decimal position and unit are the same as T
DEM
.
0 to 999999dgt (“OL” will be displayed if exceeding this range.)
Equation
(3)
Demand value (present value) (ΣDEM)
Display range
Decimal position and unit are the same as T
DEM
.
0 to 999999dgt (“OL” will be displayed if exceeding this range.)
Equation
, if
∑
Σ
=
Σ
DEMi
DEM
1
=
i
(1P2W×1)
2
=
i
(1P2W×2,1P3W,3P3W)
3
=
i
(1P2W×3,3P3W3A,3P4W)
(4) Load factor
Display range
0.00 to 9999.99% (“OL” will be displayed if exceeding this range.)
Equation
DEM
T
DEM
Σ
13.5 Other specifications
(1)AC power supply
Voltage range
AC100~240V±10%
Frequency 45~65Hz
Power consumption
10VA max
(2)DC power supply
Type
LR6: size AA (alkaline) battery x 6 pcs
Rated voltage
DC9V (=1.5V×6)
Current consumption
110mA typ.(@9V)
Battery life
approx. 15 hours (standard use, Bluetooth: OFF, Backlight: OFF)
erval
demand
of
beginning
from
Period
erval
Demand
DEM
G
DEM
int
int
×
Σ
=
(
)
erval
Demand
hour
erval
demand
of
beginning
from
WP
DEM
int
1
int
×
+
=
Σ