51

5.5

Programming Numeric Data


Various functions on the MFC 085 require numeric data to be entered by the operator. Numeric
data is always entered in the following manner.


Using setting FULL SCALE of current output, Fct. 1.3.3 as an example:


Begin from the measuring mode:






























Return to measuring mode

The flashing '0' to the left of the number to be edited allows extra digits to be added, as in
this example. If no extra digits are required, pressing the

key will cause this leading zero

to be blanked.


(0)5.0000 kg/min

(5).0000


∗∗

Some values do not allow the decimal point to be moved.


Key

Display

line 1

line 2


Fct. (1).0

OPERATOR

→↑↑

Fct. 1.(3).0

CUR.OUTP. I

→↑

Fct. 1.3.(2)

MIN. FLOW

(assume function is set to

MASS FLOW)

Fct. 1.3.(3)

MAX. FLOW

(0)

*

5.0000

kg/min

Current setting of MAX.FLOW

Units and accuracy are as

set by the format Fct. 1.2.1

(1)5.0000

kg/min

1(5).0000

kg/min

5x

1(0).0000

kg/min

10(.)

**

0000

kg/min

Decimal point may now be

moved one digit to the right for

each press of the

key

→↑

10.(1)000

kg/min

Fct. 1.3.(3)

MAX FLOW

4x