11

METER

SIZE

SIZE & TYPE

Seal is

modelled on:

STD.

MATERIAL

TYP.

TORQUE

Nm

KFTC part/drawing

ALTERN.

MAT.

TYP.

TORQUE

Nm

10 G

½” Tri-clamp

PTFE

18

3.85055.00.00

None

100 G

¾” Tri-clamp

PTFE

16

3.85155.00.00

Nitrile

+

Silicone

+

EPDM

+

Viton

+

8


8

300 G

1” IDF/ISS

Viton

8

5.85065.00.00

Nitrile

EPDM

PTFE

9

11.5

800 G

DN40
DIN11851

Viton

27.5

5.85117.00.00

Nitrile

EPDM

Silicone

24

1500 G

2” IDF/ISS

Viton

24

5.85162.00.00

Nitrile

EPDM

PTFE

26

39.5

Installation lengths for sanitary connections - please contact Krohne for further details as
installation lengths depend on customer requirements.

Typical Torque on request.

1.3

External Heating and Insulation

When installing the G+ Meter in heated and insulated pipelines, it is not generally necessary or
desirable to heat or insulate the case of the meter. This is because the central measuring tube
is not thermally coupled to the case, except at the extreme ends. It is then only necessary to
insulate the flanges as shown in the attached drawings. However, it is permissible to insulate
the case of G+ Meters and special units with heating jackets are available.

The following notes will act as a guide for use of the G+ Meter with different types of heating
and insulation systems. Please note that freezing of the product within the meter cannot
damage the meter.

1.3.1 Insulation

It is recommended that the pipework and insulation material be installed as in figure 10. The
insulation can be Rubber, Foam, Glass Fibre or any other process suitable material. It should,
however, be firmly fixed with no components such as straps or covers that can vibrate.

Figure 10

Insulation Principle