4.4
Table of programmable functions
Fct. No.
Text
Description and settings
1.0
OPERATION
Main menu 1.0 Operation
1.1.0
BASIS.PARAM
Submenu 1.1.0 Base data
1.1.1
ZERO SET
Zero adjustment. See Fct. 3.1.1
1.1.2
L.F. CUTOFF
Low flow cutoff. See Fct. 3.1.2
1.1.3
TIME CONST.
Signal converter time constant. See Fct. 3.1.3
1.1.4
STANDBY
Switching between measuring operation
and standby. See Fct. 3.1.4
1.2.0
DISPLAY
Submenu 1.2.0 Display
1.2.1
CYCL.DISP
Switching between steady display and cyclic display
1.2.2
STATUS MSG
Selects which status messages should be displayed
1.2.3
MASS FLOW
Unit for mass flow. See Fct. 3.2.3
1.2.4
MASS TOTAL
Unit for mass total. See Fct. 3.2.4
1.2.5
DENSITY
Unit for density. see Fct. 3.2.5
1.2.6
TEMPERAT
Unit for temperature. see Fct. 3.2.6
1.2.7
VOLUME.FLOW
Unit for volume flow. See Fct. 3.2.7
1.2.8
VOLUME.TOTAL
Unit for volume total. See Fct. 3.2.8
1.2.9
CONC.MEAS
Parameters for concentration measurement. See
separate concentration measurement instruction manual
1.2.10
CONC.MEAS
See 1.2.9
1.2.11
CONC.MEAS
See 1.2.9
1.3.0
CUR.OUTP. I
Submenu 1.3.0 Current output I.
1.3.1
FUNCTION I
Function current output I. see Fct. 3.3.1
1.3.2
MIN.VALUE
*
Minimum range for current output I see Fct. 3.3.3
1.3.3
MAX.VALUE
*
Maximum range for current output I see Fct. 3.3.4
1.4.0
PULS.OUTP. P
Submenu 1.4.0 Pulse, frequency output P. see Fct. 3.4.0
1.4.1
FUNCTION P
Select. Parameter to be totalized
1.4.2
PULSE/MASS *
Select. Pulse per unit
1.4.3
PULSE WIDTH *
Select pulse width in milliseconds
1.5.0
ALARM.OUT.A
Submenu 1.5.0 Process alarm output A. see Fct. 3.5.0
1.5.1
FUNCTION A
Select alarm function. See Fct. 3.5.1
1.5.2
ACTIV.LEVEL
Select. active high or low. See Fct. 3.5.2
*
Exact display depends on selected function. See sub-menu 3.3.0