KROHNE CORIMASS G-MFM 4085 EN User Manual

Page 20

background image

20

Additional input/output options

Tr

m.

No.

Option 4*

(Current and
RS485)

Option 5*

(Current and
Modbus)

Option 6

(1 Current,
1 Dual
phase pulse
output and
control
input)

Option C

(2 current,
pulse and
control
input)

Option D

(3 current

and
pulse)

Option E

(3 current

and
control
input)

Option F

(3 current

and
status
output)

5

Common
(-)

Common
(-)

Common
(-)

Common
(-)

Common
(-)

Common
(-)

Common
(-)

6

Current
output 1 (+)

Current
output 1 (+)

Current
output 1 (+)

Current
output (+)

Current
output 1 (+)

Current
output 1 (+)

Current
output 1 (+)

4

TX/RX

TX/RX

Control Input

Current
output 2 (+)

Current
output 2 (+)

Current
output 2 (+)

Current
output 2 (+)

4.1

TX/RX

TX/RX

Pulse
Output A

Control Input

Current
output 3 (+)

Current
output 3 (+)

Current
output 3 (+)

4.2

+5V

+5V

Pulse
Output B

Pulse
Output

Pulse output

Control Input

status output
(passive)

The pulse out alarm outputs where selected are passive.
*

Refer to separate RS 485 or Modbus manual

2.4

Connection of remote meters

The G meter can be supplied as remote meter with 5 m cable. Under no circumstances should
the cable be cut shorter or joined to increase its length. The meter is calibrated with this 5m
length. Any changes will influence the performance of the meter.

There are two different configurations of remote meter, on the first version the cable is fixed at
the converter end and the second has a terminal junction box at the converter end.

115

50

145